girlyjoy.pocot@concentrix.com — Coaching Report
Week of 2026-06-01 – 2026-06-07
At a Glance
| Calls Handled | Avg Handle Time | Top Product | Top Problem | Cases Documented | Cases Escalated |
|---|---|---|---|---|---|
| 31 | 11m 53s | WHW03 | SETUP | 31 | 2 |
Work Mix Lens
- Frontline-heavy week: 35 LTS queue calls vs 1 TE-owned calls.
- Coach as a frontline agent: emphasize safe troubleshooting branches, closure hygiene, and clear customer-facing next steps.
Scorecard
| Dimension | This Week | Calls Reviewed |
|---|---|---|
| Accuracy | 2.30 | 31 |
| Protocol | 1.70 | 31 |
| Communication | 2.40 | 31 |
| Overall | 2.30 | 31 |
Where Time Goes
Product Families
| Family | Calls | Avg Handle Time | Avg Overall | Avg Accuracy | Avg Protocol | Avg Communication | Note |
|---|---|---|---|---|---|---|---|
| EA | 3 | 24m 23s | 2.27 | 3.00 | 1.33 | 2.33 | Outlier: 2.5x weekly median handle time |
| MX | 12 | 16m 35s | 2.53 | 3.42 | 1.67 | 2.33 | Outlier: 1.7x weekly median handle time |
| WHW | 8 | 10m 30s | 2.45 | 2.12 | 2.00 | 2.38 | |
| MR | 5 | 9m 36s | 2.06 | 2.40 | 1.40 | 2.20 | |
| RE | 5 | 9m 32s | 2.26 | 1.20 | 1.40 | 2.20 | |
| E | 1 | 8m 16s | 1.30 | 1.00 | 1.00 | 2.00 | |
| SPN | 2 | 6m 16s | 2.75 | 2.50 | 1.50 | 2.50 |
Key Observations
- EA is the slowest family at 24m 23s; outlier: 2.5x weekly median handle time.
- MX is the slowest family at 16m 35s; outlier: 1.7x weekly median handle time.
Problem Categories
| Category | Calls | Avg Handle Time | Avg Overall | Avg Accuracy | Avg Protocol | Avg Communication | Focus Area? |
|---|---|---|---|---|---|---|---|
| SETUP | 13 | 13m 58s | 2.10 | 2.50 | 1.50 | 2.30 | ✓ |
| ACCESS | 7 | 10m 14s | 2.20 | 2.40 | 1.60 | 2.40 | ✓ |
| CONNECTIVITY | 9 | 10m 40s | 2.50 | 3.10 | 1.90 | 2.60 | |
| CONFIGURATION | 1 | 9m 38s | 2.80 | 5.00 | 2.00 | 2.00 |
Week-over-Week Movement
- Average handle time moved down by 2m 20s.
- Family swing: EA handle time moved up by 17m 56s vs. last week.
- Family swing: E handle time moved down by 10m 35s vs. last week.
- Family swing: MR handle time moved down by 9m 06s vs. last week.
What Went Well
- Accurate model-specific guidance
> "For LN Series nodes, hold the reset button for five presses to pair successfully."
- Effective resolution confirmation
> "The exclamation mark disappeared, and the node showed online in the app."
- Clear next-step communication
> "I’ll email the setup guide and schedule a callback if needed."
Growth Opportunities
- Collect essential device details
> "I need the model and serial number to proceed." (missing in calls like #LTS00132316)
Next step: Always ask for model/serial in the opening script. Verify warranty status before proceeding.
- Use correct default credentials and URLs
> "The default password for E1200 is admin/admin, not admin/1234."
Next step: Reference KB for default credentials. Use myrouter.local or [REDACTED_PHONE] for admin access; avoid incorrect URLs like myrouter.cal.
Next Week's Focus
- Start every call with model/serial collection – add to opening script and confirm before troubleshooting.
- Practice warranty lookup – use serial number to verify eligibility before offering paid support.
- Standardize password-reset flow – for WHW/MX/E-series, guide to recovery key on device label, then
myrouter.infoor direct URL. - Confirm resolution verbally – e.g., "Can you now access the admin page?" before closing.
Technical Accuracy
Improvement
- Wrong default credentials: Provided
admin/1234for E1200 (correct:admin/admin).
Improvement
- PCI DSS violation: Collected full credit card details over unsecured line.
Improvement
- Incorrect URL: Used
myrouter.calinstead ofmyrouter.localfor MX8500.
Strength
- Accurate pairing method: Correctly guided 5-press reset for LN Series Cognitive Mesh.
Coaching Moments
Improvement
"Email/password login is no longer supported for this model."
Note: Incorrectly stated Linksys Smart Wi-Fi website discontinuation, contradicting KB.
#LTS00131863
Improvement
"Hold the reset button for 30 seconds."
Note: Wrong reset duration for RE6300 (KB: 10 seconds).
#LTS00132224
Escalation Lessons: What L2 Did
#TE00131644 — Resolved by Level 2
- What L1 saw: Customer reset EA8300, couldn’t access admin page (
myrouter.localfailed). - Why it escalated: L1 provided incorrect URLs (
myrouter.info,linxys02812.com) and failed to verify model. - What L2 did:
1. Confirmed model EA8300 ( Intelligent Mesh ).
2. Guided 5-press pairing on parent node.
3. Verified access via http://[REDACTED_PHONE]/ui/local/dynamic/index.html.
- Current state: Resolved.
- L1 learning points:
- Confirm model before suggesting URLs.
- Use direct URL workaround for EA/MX series when myrouter.local fails.
- Validate LED states (solid purple = ready).
#LTS00132316 — Resolved by Level 2
- What L1 saw: MX8500 child node showed blinking orange, no admin access.
- Why it escalated: L1 advised node swap without attempting factory reset or URL verification.
- What L2 did:
1. Instructed full factory reset (hold reset until LED off).
2. Guided 5-press pairing on parent node.
3. Confirmed access via myrouter.local.
- Current state: Resolved.
- L1 learning points:
- Attempt factory reset before node swap.
- Use myrouter.local or direct URL; never myrouter.cal.
- Collect serial number to confirm warranty and model compatibility.
Coach Appendix
- Top trend: Inconsistent model/serial collection and warranty verification, leading to inaccurate guidance and escalations.
- Recurring pattern: Over-reliance on self-help emails without confirming resolution or providing actionable next steps.
- Critical focus: Standardize opening scripts for model/serial capture, practice warranty lookups, and verify resolution before closure.
This Week's Calls
| Case | Date | Score | Direction | Product | Category | Outcome |
|---|---|---|---|---|---|---|
| #LTS00127328 | 2026-06-01 13:47:56+00:00 | 1.3 | INBOUND | E1200 | ACCESS | ⚠ Closed incorrectly |
| #LTS00131479 | 2026-06-01 15:04:11+00:00 | 2.8 | INBOUND | MX5500 | CONNECTIVITY | ✓ Likely resolved |
| #LTS00131635 | 2026-06-01 16:10:23+00:00 | 2.8 | INBOUND | MR7500 | CONNECTIVITY | ⏳ Pending |
| #LTS00131636 | 2026-06-01 16:23:29+00:00 | 2.8 | INBOUND | SPNM60TB | ACCESS | ✓ Likely resolved |
| #TE00131644 | 2026-06-01 17:04:52+00:00 | 1.8 | INBOUND | EA8300 | SETUP | ↑ Escalated |
| #LTS00104206 | 2026-06-01 17:19:12+00:00 | 1.8 | INBOUND | MX4200 | SETUP | Abandoned |
| #LTS00132316 | 2026-06-01 17:50:31+00:00 | 1.8 | INBOUND | MX8500 | ACCESS | Pending |
| #LTS00131694 | 2026-06-01 20:23:20+00:00 | 1.4 | INBOUND | WHW03 | CONNECTIVITY | ⏳ Pending |
| #LTS00131699 | 2026-06-01 20:37:49+00:00 | 2.8 | INBOUND | EA7300 | SETUP | ⏳ Pending |
| #LTS00131670 | 2026-06-01 21:25:56+00:00 | 2.8 | INBOUND | WHW03 | CONNECTIVITY | ⏳ Pending |
| #LTS00131850 | 2026-06-02 16:19:11+00:00 | 1.3 | INBOUND | MR75MS | SETUP | ⏳ Pending |
| #LTS00131859 | 2026-06-02 16:53:23+00:00 | 3.1 | INBOUND | MX2000 | CONNECTIVITY | ⏳ Pending |
| #LTS00131863 | 2026-06-02 17:08:42+00:00 | 1.4 | INBOUND | WHW03 | ACCESS | ⏳ Pending |
| #LTS00131876 | 2026-06-02 17:57:19+00:00 | 2.8 | INBOUND | MR7350 | CONNECTIVITY | ⏳ Pending |
| #LTS00131889 | 2026-06-02 19:21:19+00:00 | 1.8 | INBOUND | MR8300 | ACCESS | ⏳ Pending |
| #LTS00131907 | 2026-06-02 20:28:23+00:00 | 2.8 | INBOUND | RE6300 | SETUP | ⏳ Pending |
| #LTS00131922 | 2026-06-02 21:21:43+00:00 | 2.8 | INBOUND | MX2000 | SETUP | ✓ Resolved |
| #LTS00132026 | 2026-06-03 14:53:37+00:00 | 2.8 | INBOUND | WHW03 | SETUP | ⏳ Pending |
| #LTS00132056 | 2026-06-03 16:47:11+00:00 | 1.6 | INBOUND | MR7500 | SETUP | ⏳ Pending |
| #LTS00132077 | 2026-06-03 17:31:29+00:00 | 3.9 | INBOUND | WHW03 | CONNECTIVITY | ✓ Resolved |
| #LTS00132127 | 2026-06-04 13:08:25+00:00 | 2.8 | INBOUND | MX6200 | CONFIGURATION | ↻ Callback set |
| #LTS00132224 | 2026-06-04 13:22:16+00:00 | 2.8 | INBOUND | RE6300 | SETUP | ⏳ Pending |
| #LTS00132234 | 2026-06-04 14:03:13+00:00 | 2.8 | INBOUND | RE6500 | SETUP | ⏳ Pending |
| #LTS00132264 | 2026-06-04 16:27:08+00:00 | 1.6 | INBOUND | RE7350 | SETUP | ⏳ Pending |
| #LTS00132283 | 2026-06-04 17:36:18+00:00 | 2.4 | INBOUND | MX2000 | CONNECTIVITY | ↻ Callback set |
| #LTS00132283 | 2026-06-04 18:09:04+00:00 | 2.8 | INBOUND | MX2000 | CONNECTIVITY | ↻ Callback set |
| #LTS00132316 | 2026-06-04 20:12:47+00:00 | 3.6 | INBOUND | MX8500 | ACCESS | ✓ Resolved |
| #LTS00132405 | 2026-06-05 13:55:55+00:00 | 2.7 | INBOUND | SPNM60CF | SETUP | ⏳ Pending |
| #LTS00132415 | 2026-06-05 14:42:44+00:00 | 2.8 | INBOUND | WHW03 | ACCESS | ⏳ Pending |
| #LTS00132424 | 2026-06-05 15:51:32+00:00 | 2.2 | INBOUND | EA8300 | SETUP | ⏳ Pending |
| #LTS00065248 | 2026-06-05 17:58:59+00:00 | 2.8 | INBOUND | WHW01 | CONNECTIVITY | ⏳ Pending |
| #LTS00129054 | 2026-06-05 20:32:23+00:00 | 1.3 | INBOUND | RE6700 | SETUP | ⏳ Pending |
| #LTS00104206 | 2026-06-05 22:52:06+00:00 | 2.8 | OUTBOUND | MX4200 | SETUP | ✓ Resolved |
| #LTS00067885 | 2026-06-06 02:21:39+00:00 | 1.8 | INBOUND | MX6200 | SETUP | Abandoned |