1Calls
3.00Avg Score
8m 33sAvg Handle Time
0Documented
0Escalated
Week-over-Week Progress
Scorecard
| Dimension | Week Average | Calls Reviewed |
|---|---|---|
| Overall | 3.0 | 1 |
| Technical Accuracy | 1.0 | 1 |
| Protocol | 2.0 | 1 |
| Communication | 3.0 | 1 |
Main focus: LED state interpretation
V2 Rubric (Shadow Grading)
V2 overall: 81.25% across 1 v2-scored calls this week
| Category | Week Average |
|---|---|
| Resolution | 3.75 |
| Technical Accuracy | 3.12 |
| Communication | 3.75 |
| Customer Ownership | 5.0 |
| Escalation Judgment | 5.0 |
| Customer Experience | 5.0 |
- Successful Resolution: 1
Where Did the Time Go
Product family breakdown not available.
By Problem Category
| Category | Calls | Avg Handle Time | Overall | Accuracy | Protocol | Comms | Focus? |
|---|---|---|---|---|---|---|---|
| CONNECTIVITY | 1 | 8m 33s | 3.0 | 1.0 | 2.0 | 3.0 |
What You Did Well
- Accurate serial verification1 of 1 callsCollected and verified the customer-provided serial number accurately, ensuring correct device identification for troubleshooting.Why this matters: Prevents misdirected support and ensures appropriate resolution steps.
- Effective 5-press resolution1 of 1 callsCorrectly applied the 5-press pairing method which successfully restored connectivity to the mesh child node.Why this matters: Delivered immediate customer satisfaction through technical proficiency.
Growth Focus
- LED state interpretation1 of 1 callsIncorrectly stated solid red LED indicates setup mode, contradicting KB documentation which defines it as 'No internet connection'. This misinformation could mislead customers.Why this matters: Technical inaccuracies erode trust and may lead to repeated issues or unsafe actions.Example: At 02:00, agent claimed 'solid red for this specific node indicates that it is like on setup mode' which is factually incorrect per led_intelligent_mesh_consumer.md.What better looks like: Reference KB documentation for LED meanings specific to the reported product model before explaining status indicators.
- Model verification before procedures1 of 1 callsFailed to confirm product model before recommending the 5-press method, creating risk of incorrect procedure application on unsupported models like SPNM/LN series.Why this matters: Applying model-specific procedures to incompatible hardware can cause permanent damage or extended downtime.Example: Agent recommended 5-press pairing without verifying the child node model, though it resolved correctly for this Velop system.What better looks like: Always confirm product model and consult universal_5press_models.md before recommending advanced recovery procedures.
Callback Flags
No callback chains detected.
Documentation Accuracy
No documentation mismatches detected this week.
Practice Plan
- Step 1Before explaining LED status meanings, open the KB article for the specific product model and verify definitions with the customer.Why: Preventing technical misinformation avoids customer confusion and reduces callback risk.
- Step 2When recommending advanced procedures like 5-press pairing, explicitly confirm the product model against supported lists before proceeding.Why: Ensures procedures are applied only to compatible hardware, preventing damage or ineffective troubleshooting.
- Step 3After guiding customers through troubleshooting steps, ask them to verbally confirm observed outcomes (e.g., 'Do you now see solid white on both nodes?').Why: Direct confirmation reduces misinterpretation and verifies resolution before closing.
Escalation Lessons
No escalated case learning this week.
Evidence Calls
| Case | Date | Score | V2 | Product | Category | Outcome |
|---|---|---|---|---|---|---|
| 15474352-6f06-11f1-a42a-42010a62006fINBOUND | 2026-06-23 | 3 A 1P 2C 3 | 81.2% Developing | CONNECTIVITY | Node rejoined the mesh; customer can now relocate the node. |