3Calls
3.20Avg Score
33m 23sAvg Handle Time
3Documented
0Escalated
Week-over-Week Progress
Scorecard
| Dimension | Week Average | Calls Reviewed |
|---|---|---|
| Overall | 3.2 | 3 |
| Technical Accuracy | 3.67 | 3 |
| Protocol | 3.0 | 3 |
| Communication | 2.0 | 3 |
Main focus: Technical accuracy verification
V2 Rubric (Shadow Grading)
V2 overall: 34.39% across 3 v2-scored calls this week
| Category | Week Average |
|---|---|
| Resolution | 1.88 |
| Technical Accuracy | 1.15 |
| Communication | 2.08 |
| Customer Ownership | 1.69 |
| Escalation Judgment | 0.0 |
| Customer Experience | 2.02 |
- Partial Resolution: 2
- Unresolved: 1
Where Did the Time Go
By Product Family
| Family | Calls | Avg Handle Time | Overall | Accuracy | Protocol | Comms | Note |
|---|---|---|---|---|---|---|---|
| MX | 2 | 40m 22s | 3.25 | 3.0 | 3.5 | 2.0 | |
| E | 1 | 19m 25s | 3.1 | 5.0 | 2.0 | 2.0 |
By Problem Category
| Category | Calls | Avg Handle Time | Overall | Accuracy | Protocol | Comms | Focus? |
|---|---|---|---|---|---|---|---|
| CONNECTIVITY | 1 | 60m 46s | 3.7 | 5.0 | 4.0 | 2.0 | |
| NO TROUBLESHOOTING NEEDED | 1 | 19m 57s | 2.8 | 1.0 | 3.0 | 2.0 | |
| SETUP | 1 | 19m 25s | 3.1 | 5.0 | 2.0 | 2.0 |
What You Did Well
- Device identification accuracy2 of 3 callsCorrectly identified the E1200 as obsolete and no longer supported, aligning with KB guidance across 1 of 3 calls (#EOS00136290). Confirmed MR9000 model and serial number accurately across 1 of 3 calls (#LTS00136293).Why this matters: Prevents customers from attempting unsupported configurations on end-of-life devices
- Mesh restoration execution1 of 3 callsAccurately guided factory reset of blinking red nodes using 20-second hold and properly applied the 5-press pairing method on MX4200, restoring mesh connectivity across 1 of 3 calls (#LTS00100300).Why this matters: Enables customers to recover mesh networks after power disruptions without escalation
Growth Focus
- Technical accuracy verification2 of 3 callsIncorrectly stated any Linksys mesh product works with MR9000 (contradicting KB) and misnamed non-existent products across 1 of 3 calls (#LTS00136293). Failed to verify internet connectivity after mesh restoration across 2 of 3 calls (#EOS00136290, #LTS00100300).Why this matters: Leads to customer purchasing incompatible hardware and creates support reworkExample: Told customer any mesh node works with MR9000 (call #LTS00136293) despite KB stating cross-generation incompatibilityWhat better looks like: Validate mesh compatibility against KB before recommending products and always verify internet connectivity post-troubleshooting
- Troubleshooting completeness2 of 3 callsFailed to perform basic troubleshooting (power cycle, LED checks) and omitted serial number collection across 1 of 3 calls (#EOS00136290). Provided ambiguous reset instructions ('press release press release') across 1 of 3 calls (#LTS00100300).Why this matters: Reduces first-call resolution and increases callback riskExample: Advised replacement of obsolete E1200 without any diagnostic steps (call #EOS00136290)What better looks like: Follow documented troubleshooting sequence and collect device identifiers before declaring hardware obsolete
Callback Flags
No callback chains detected.
Documentation Accuracy
No documentation mismatches detected this week.
Practice Plan
- Step 1Always verify internet connectivity and Wi-Fi functionality using KB-documented steps after completing mesh restorationsWhy: Prevents unresolved connectivity issues that lead to callbacksThis week: #LTS00100300
- Step 2Consult velop_mesh_compatibility.md before recommending any mesh node for MR9000 or other Intelligent Mesh routersWhy: Avoids selling customers incompatible hardware that renders networks non-functionalThis week: #LTS00136293
- Step 3Collect serial number, ISP information, and firmware version during initial device identificationWhy: Enables proper diagnostics and warranty validationThis week: #EOS00136290
Escalation Lessons
No escalated case learning this week.
Evidence Calls
| Case | Date | Score | V2 | Product | Category | Outcome |
|---|---|---|---|---|---|---|
| #EOS00136290INBOUND | 2026-07-08 | 3.1 A 5P 2C 2 | 7.5% Needs Improvement | E1200 | SETUP | Advised replacement of the obsolete router. |
| #LTS00136293INBOUND | 2026-07-08 | 2.8 A 1P 3C 2 | 21.5% Needs Improvement | MX2000 | NO TROUBLESHOOTING NEEDED | Advised to purchase a Linksys mesh node (e.g., Atlas Wi-Fi 6) for coverage extension, despite incompatibility risks. |
| #LTS00100300INBOUND | 2026-07-08 | 3.7 A 5P 4C 2 | 74.2% Developing | MX4200 | CONNECTIVITY | Most nodes show solid green/blue; mesh appears restored. Customer later confirmed Wi-Fi working during app check. Case closed with case number 100 300. |
Feedback
✓ Feedback submitted — thank you!